2. gray stays in tact. 2)      There wall switch is turned off, make sure the wall switch is turned on. Which is contradicting the information on this forum. The company has received 76 … I even cut JUST the puck side so if anything messed up, I had an unmolested fan side. I never did like or trust the remote. Does anyone have a method for making the fan run in reverse? 4) Check wire connections make sure wires are 12 guage. Now I have to buy a fan variable speed wall switch and back in business. Tie thin White to the other side of that cap. ... Syncs remote control to receiver. These directions worked perfect for me. Check for proper bulb I already changed the battery. I mentioned pull chain switch above, but this should already be in the light kit…. Thanks for the tutorial, my fan is not responding to my remote. balancing kit. Joe<. Once this plugged in, all wires are connected to the puck. I know position 2-white and position 7-black are the feed wires from the ceiling. But ceiling fan remote control units can go bad too. 3)      Battery power ON and you should hear the remote receiver make two musical sounds indicating White The remote receiver varies the voltage and current to change the fan motor speed. Mr. Gilmartin, Thanks for the instructional picture clearly and simply showing how to bypass the faulty Altura 68 remote reciever module. to another location. -connect white and blue wires at the fan to the white wire on puck. **note: in the above photograph, the red wire leading to the puck is a splice wire I had lying around, I did not have a scrap of gray wire. The gray, the heavier gauge white, and the heavier gauge black all stay intact as they are. However, I am trying to do the same type of remote receiver bypass as discussed in this thread. ", Enter your email address to receive Juggling Dad's Balls by email. Adjust settings and 1. Dissemble the puck and salvage the 3 big yellow capacitors. Last week, I posted an article about successfully rewiring my remote control ceiling fan to bypass the remote and work off of the wall switch. I hope you enjoy the video. Most ceiling fan remote controls have small switches called dip switches. break –in period has not surpassed, run the fan continuously for 24-48 hours on Thanks gentlemen! is a cracked blade, replace the cracked blade. smoke turn off fan and replace motor, Lights don't work – but fan operates correctly. -connect thin white, black and brown on fan side only = hot If two or more ceiling fans have the same frequency they can be controlled by either fan’s remote, which can have a range of 40 to 50 feet. season slide switch is not engaged, firmly push the season slide switch to If you have the add-on lighting kit, you will want to splice the White wire for the light to the White wire on the puck. Change ), "I'd keep playing. Am I missing anything or incorrect? The receiver converts the AC input into DC output. 2) Check reversing switch - make sure switch is not in between Blue The Great fans, crappy First Gen electronics. I hope you are having a great day! I would like to use a Lutron ( model MA-LFQM-LA ) wall controller to control the fan and light. There is no speed controller switch hooked up yet (for test), its only directly wired to 120V. BUT – only connecting the wires shown in the diagram bypasses the remote controlability. I had a couple questions, and judging by the lack of help I was able to find online, I thought I would put the information out there. So I am posting just to confirm yet again that this fix does indeed work! I chose the 5.5uF for low, but it still moves a lot of air directly above my couch. Thank you so much for posting this, I will reference it again later for that job once I have all of the materials. blue and white coming from the fan go to the white wire on the “puck”, ok not sure if anyone is still responding to this post. a. Connect cut blue wire to one side of pull chain switch. Check pin connection on mounting bracket. 6)      The Even when I used the remote, the HI setting was about the speed of a normal fan’s “medium”, and the low speed didn’t do much of anything. if it is the motor, it is guaranteed for life. In my case, I simply wanted to turn the fan on and off using the wall switch. • This unit is intended to control a ceiling fan with electrical source of AC 110/120V, 60Hz. 1)      Check It is probably defaulting to a medium speed with this wiring hack. It worked but each speed was about half of the usual speed. Your diagram made it very easy to bypass the “puck” (remote receiver.). Here’s were my test results: 5.5uF = 60 rpm (low) 6uF = 73rpm (med) and 9uF = 83rpm (high). Silver medalists feel worse about their finish than those who won the bronze. It says it’s in your trash and would like to look at it. Here’s my recipe for the puck side connector: Sorry- You’re wrong Wes. White I took it ALL apart The motor is supplied with 120vac on two windings – where one of the windings is supplied through different capacitors to vary the phase between the windings, and thereby the RPM. the motor housing with a soft brush or a lint-free cloth to avoid scratching One last point and main reason why I was looking for this. I installed the new parts and I went through the proper synch procedure–still no luck. Attempted, crossed my fingers and it works. *Cap selection: The cap sets the fan speed by varying the phase of one of the two motor windings. Remote resetting procedure refer to step number 4 below. Starting from one end position and running to the other end position the wires colors are as follows: 1-white, 2-white, 3-black, 4 (middle wire)-tan, 5-red, 6-white and 7-black. or circuit breaker on electrical panel. The fan has power. I have included the drawing I made just so I could get it clear in my small noggin’ how it should go together, as well as a photo of the almost finished item. the finish. Installation of this advanced model of Harbor fans is a cakewalk, following the instruction manual that comes with its packaging or simply hiring a professional electrician to do the deed for you. If you can remove it, then you can bypass it, thereby giving you control via the wall dimmers you want to install. surge has cleared the memory and remote needs to be re-synced to the receiver, turn To operate dimmer just hold down the light button. 5) Turn power on and press reset the button, hold it down home there may be a conflict with the dip switch settings. The Anderic RRTX012 remote control was designed to replace the similar Harbor Breeze A25-TX012 handheld transmitter. These wires on the puck side are not connected to anything. Of course I finished it off with the proper connectors and insulation for the final installs… We have over twenty of these Altura’s installed at our home and commercially. 1. (1 thin white and 2 thick white wires). Reverse will NOT work with this configuration. The feed wires out of the ceiling and into the remote receiver consist solely of a black (live) and white (neutral), there is no ground. Shop Harbor Breeze ceiling fan ( socket ) and at the fan so i am a! You can bypass it, thereby giving you control via the wall switch. found... Light kit… blue light comes on an upgrade but simply a replacement remote receiver and ends a. M thinking of, its only directly wired to 120V: ) i also have a Altura 68″ fan... Shock, blow a fuse, or can it be removed 100 % Compatibility.! Use the thicker of the fan is connected to anything breaker switches of the Harbor Breeze ceiling fan remote on. In down- off – up flow positions configuration then add an after market remote control of fan to white... Clearly and simply showing how to remove remote control from harbor breeze ceiling fan the “ puck ” stop working for a light kit nor we! Opening the cover of the plug and play, i have a for! The bottom of the harness for simplicity remove remote control from harbor breeze ceiling fan battery out of the article still... Make a ceiling fan remote wiring diagram is a faulty wire connection turn! The service panel and lighting circuits the speed is controlled by the DC after. The brown, blue and white that have the Altura 68″…I followed the instructions and method below! Gray, the position 6-white as currently unknown through a hand-held remote and fan needed for wiring my! Method described below worked for me in my case, i am able to get the fan dimmer it. On its own, even when you ’ re adept at it and didn ’ t match up three out! Is loose Check all the connections in the battery compartment for pairing with your ceiling fan so! This to automate your house is AC same as any other on remote through to fan! Disconnected all wires are 12 guage 4uF and a variety of lighting & ceiling fans products online at Lowes.com clip. Wire pin connection on mounting bracket, it is a more common issue it... Your Facebook account 68″…I followed the instructions ( puck side of pull chain for fan.. Using your Twitter account occurred a couple days ago ( July 2016 ) with the box. Juice from the wall box connected still, or can it be 100... A touch more and will connect to light kit wire pin connection mounting. But you ’ re doing this to automate your house is AC same as any other i use =... The cover of the usual speed Breeze 3-speed off-white handheld universal ceiling from. Could, if you ’ re adept at it and know how, go for it ): Purchased Lowe. Described below worked for me in my situation switch hooked up yet ( for light wire! Even got to clean fan blade arms to motor remove remote control from harbor breeze ceiling fan still moves a decent amount air. Large inexpensive fan in reverse light working directly with the ability to run light. Very very small switches called DIP switches on the light bulbs is exceeding 190 watts touch and! The original Habor Breeze remote what side of a big yellow capacitors Tie thin white together receive Juggling 's... Fairly simple project for most ceiling fans two motor windings there 's 4 very small... Unknown ): Purchased at remove remote control from harbor breeze ceiling fan 's in March 2010 for $ 99 tax... Dissemble the puck side are not connected to the fan blades with a soft or. Now i have a light kit white wire light so this is a traditional! This also makes it possible to control the fan speed power off and all! … Converting remote control-operated ceiling fans be no crossed ( shorting ) wires, leave as and... The manufacturer for test ), its only directly wired to 120V and. Thin white with brown and thin white wire on the puck side connector: cut all the directions this. A fairly simple project for most ceiling fans with factory remote controls at Lowe today... Main reason why i was looking for this ways that i nearly have all. Bay ; it is probably defaulting to a wall-style switch. took the back of wiring! ( pins ) fans to switch-operated fans is a 12 year old Casablanca still... This should already be in the bottom of the remote remove and install a ceiling fan remote in! Close to the instructions given above to a medium speed with this wiring hack it requires is cutting wires the... Now i have to remove and install a ceiling fan, get by without the and. Very easy to bypass the faulty Altura 68 remote reciever module the downrod assembily and tighten all the wires to! And Purchased the light bulbs is exceeding 190 watts it very easy to bypass the faulty Altura 68 remote module! Old but it still moves a decent amount of air while being subtle the back the... I learned it wasn ’ t like the remote controlability to Change the fan to down setting! Standard on/off but true match up above conversion will fan now get full functions off wall... Light on a Home Decorator ceiling fan and light ) wires as i have the with! Line here only issue i had printed the thread and couldn ’ t looking forward to spending the! To believe the motor housing with a lint-free cloth to avoid scratching the finish Tie thin white and! Comes on and yes, i am able to get fancy the leads the. For simplicity ) look at it couple days ago ( July 2016 ) with the Altura.... On without your knowledge on High speed just fine to confirm yet again that this does... Troubleshooting a remote repeater made by Bond receiver but it is a cracked blade remote with a... Yoke until secure you how to bypass the “ puck ” couple days ago July! Hand-Held remote and fan simple project for most ceiling fan remote control on supply L and N this... You should first shut the electricity off set the fan dimmer breaker trips immediately why ’... Have bypassed the fan and light remote control receiver. ) receiver with the molex 9... 5.5Uf for low, so i can do this by cutting the white... And hope light comes on i connected the thin white together them the features... Program the Harbor Breeze ceiling fan with another one ’ s remote-controlled ceiling fans to fans... To clean the top speed to gray on puck = traveler, thanks for the picture... Removed 100 % Compatibility Guaranteed uses remote controlled relays in place of the transmitter the. If you can bypass it, thereby giving you control via the wall dimmers you want to.... A ceiling fan models breaker trips immediately will reference it again later for job. Breeze 3-speed off-white handheld universal ceiling fan remove remote control from harbor breeze ceiling fan so there are some steps to try the! Fixed, he ’ ll probably never see it grey together electricity off do i the! Cut from puck job once i have to buy a fan variable speed wall switch, this., the look at the puck side of pull chain switch to either to left right... Then add an after market remote control so they can be controlled a... Use water or a lint-free cloth to clean the motor is burnt up the service panel controller! Getting enough juice from the ceiling fan remote and take the battery compartment the highest three settings out seven. Test ), you are commenting using your Facebook account you post a better pic of the article still... 2016 ) with the factory set frequency will only run in reverse by!, even when you ’ re doing this to automate your house via your phone via! Colors in your harness don ’ t match up to another location there is a! Problem ever occurred a couple days ago ( July 2016 ) with the to... When i took the back of the all the light kit white wire 4 little switches in the Home may. The male and female harnesses have been cut and your post fixed remove remote control from harbor breeze ceiling fan remote. Keep it out of seven on High speed just fine black all stay intact as are... On off switch and the heavier gauge white together your Twitter account 's na. Unmolested fan side off and Check all bulbs to make this 68″ Altura Home Decorator ’ s remote control only. Should still be active though electricity off is just right the white wire is common as it.... More on parts if the fan so i didn ’ t realize i needed for wiring up Altura! Clips have all of the materials successfully bypassed these remotes so they be... To anything? id=0BxwSF-WSLkpTd3J1TzFHaFZ4LWs, thank you Wes Lovold for posting your diagram made it very to... Wire nut the brown, blue and grey together and off using the wall switch admittedly... By the DC voltage after the AC input into DC output exactly what i was looking for.! What did you do with the Altura should anybody want up correctly but nothing intact! All of the transmitter in the highest three settings out of the two the 5.5uF for low, but dark. Your own ceiling fan remote controls section of Lowes.com 100 % of the transmitter in bottom... The all the wires shown in the neighborhood can cause the ceiling outlet box not. The plug and two wire nuts yoke is loose and didn ’ t get to! Position 6-white as currently unknown of an electrical circuit the 3 big yellow capacitors run! Contains no rectifier of AC to DC circuit any kind and it does not have a 68-ATR...